Introduction To Capacitors And Reactors Reactance includes inductive reactance and capacitive reactance, and reactor includes inductive reactance (inductor) and capacitive reactance (capacitor). Inductance has the function of blocking AC and blocking DC, that is, in the AC circuit, the characteristics of inductive reactance are used to pass low-frequency DC and block high-frequency AC. The capacit...
what are the effects of harmonics on electrical systems In the intricate realm of electrical engineering, harmonics emerge as a subtle yet influential phenomenon that can significantly impact the efficiency, reliability, and safety of electrical systems. These unwanted frequencies, riding alongside the fundamental power waveform, can wreak havoc on various components and overall system perf...
Introduction This blog compares harmonic mitigation techniques across various applications in real time. It examines different aspects of active and passive series and shunt filters, focusing on reducing harmonic loading in drive systems. It discusses the pros and cons of parallel and series approaches, as well as active and passive solutions, supplemented by practical results from several case st...
Harmonic Resonance Evaluation for Capacitor Banks Abstract: A utility operates feeder and substation capacitor banks on a 25.56kV distribution feeder. The utility uses frequency scan simulations to determine the effect of distribution feeder and substation capacitor banks on harmonic resonance and frequency response characteristics. It is assumed that the simulations will show that the f...
What are the differences between SVG and capacitors? SVG (Static Var Generator) and traditional capacitor banks serve the common purpose of reactive power compensation in electrical power systems, yet they diverge considerably in their operational mechanisms, performance attributes, and adaptability. Below is an elaboration comparing these methodologies: 1. Operation: - ...
Resonance and Active Harmonic Filters Resonance in power systems can lead to significant issues such as harmonic amplification, overvoltages, and equipment damage. Active Harmonic Filters (AHFs) play a crucial role in mitigating harmonic distortion and preventing resonance. Understanding how resonance occurs and how AHF can be used to manage it is key to maintaining a stable and efficient electric...
How to do power factor correction?Introduction to Power Factor Correction: Importance and Design The growing integration of photovoltaic (PV) systems into the grid has created challenges for utility providers. One of the primary concerns is that many power electronics used in these systems consume reactive power, leading to a low power factor and system instability. As a result, power factor corre...
Dynamic Voltage Restorer: The Guardian of Power Systems In modern industrial and commercial applications, maintaining power quality is crucial for the reliable operation of sensitive equipment. One of the major challenges in power quality is voltage sags and dips, which can disrupt operations and cause equipment malfunction. Enter the Dynamic Voltage Restorer (DVR) – a critical piece of equi...