YTPQC-AHF Active Harmonic Filters YTPQC-AHF Active Harmonic Filters(AHF) provide a solution for real-time cancellation of harmonic distortions created by non-linear loads to ensure compliance with IEEE 519, G5/4, EN 50160 and also other power quality standards and recommendations. YTPQC Active Harmonic Filters are a versatile solution, easily tailored to deliver power factor improvement, voltage v...
YTPQC-SVG Static Var GENERATOR Static Var Generator SVG works as a dynamic reactive power source, adopts high-speed computation components like DSP/IGBT, combining with super precise control program, following the grid current variation in real time, improving Power Factor value to 0.99 within 5ms. SVG represents the latest generation technology in the power factor correction field. By elimi...
The Active Harmonic Filter AHF unit is an electronic measuring instrument used in natural science-related engineering and technical fields. During the spurious emission process of communication equipment, the wireless communication signals in the GSM, GSMR and CDMA frequency bands are filtered, which generally consists of capacitors, resistors and inductors. During the operation of the AHF Harmoni...
The inductor is a component that can convert electrical energy into magnetic energy and store it. The structure of the inductor is similar to that of a transformer, but there is only one winding, which only hinders the change of current. If the inductor is in the state of no current passing through, when the circuit is connected It will try to hinder the flow of current through it. If the inductor...
Power Factor Correction Power Factor Correction improves the phase angle between the supply voltage and current while the real power consumption in watts remains the same, because as we have seen a pure reactance does not consume any real power. Adding an impedance in the form of capacitve reactance in parallel with the coil above will decrease Θ and thus increases the power f...
Meaning Of Harmonics Harmonic refers to the electric quantity whose frequency is an integral multiple of the fundamental wave contained in the current. Generally, it refers to the Fourier series decomposition of the periodic non sinusoidal electric quantity. Except for the electric quantity of the fundamental wave frequency, the electric quantity generated by the current greater than the fundament...
Electricity is a big part of our day, powering all the tech we use. There are two main types of electricity users, or "loads," called linear and non-linear. This just means they use electricity from the power supply in different ways. This distinction affects everything from power efficiency to the longevity of devices. Categories of Electrical Loads: · Inductive Loads: Characterized b...
Effects of Harmonics : Increased losses Losses in capacitors The harmonic voltages applied to capacitors cause the flow of currents proportional to the frequency of the harmonics. These currents cause additional losses. Losses in conductors The active power transmitted to a load is a function of the fundamental component I1 of the current. When the current drawn by the load contains harmonics...