What are scenarios causing power factor displacements 1. Poorly designed electrical systems with inadequate power factor correction equipment. 2. Large inductive loads such as motors, transformers, and generators that cause lagging power factor. 3. Unbalanced three-phase loads that cause phase displacement of the current and voltage waveforms. 4. Unbalanced single-phase loads that cause current an...
Power Quality Power electronics make modern life possible and enable all other areas of innovation. Although stable power delivery seems like a simple problem, the design of a high-efficiency power transmission and conversion system is prone to several problems that reduce efficiency by reducing delivered power. Nonlinear components are needed in power electronics to control the flow of power and ...
Basic Information Downstream line-to-line voltage (V): 1). 208V/220V 2). 380V/400V/415V 3).440V/460V/480V 4).600V/660V/690V System Rated Frequency: 1). 50Hz 2). 60Hz System phase connection: 1). 3P4W 2). 3P3W Other Useful Information 1). Upstream short circuit power 2). Transformer rated power(kVA) 3). Short circuit impedance(6.5%?) 4). Max load(kW) 5). Ambient temperature 6). Rated Hu...
Microgrids are designed to operate at a fundamental frequency (50 or 60 Hz). However, certain types of loads generate voltage and/or current harmonics that increase power system heat losses. These harmonic losses reduce system efficiency, cause apparatus overheating and increase power costs. Besides that, the Distributed Generation (DG) is expected to play an important role in future power systems...
Achieving capable factory functional test requires meeting multiple criteria to ensure the highest quality product. These criteria include test capability and repeatability, system upgradability and supportability, and production scalability. Setting up new production test not only involves implementing new test systems, but also managing schedule risk and budget which are often impacted by techni...
For all clients, We adhere to quality-oriented, try our best to meet customer's technical requirement. Our client also has a good,professional technical team, they buy our modules to build cabinet locally in Australia. Since we worked with Australian clients, they have build Static Var Generator(SVG) panel, Active Harmonic Filter(AHF) panel, and hybrid SVG and AHF panel. This customer's visit gave...
Backgaround With the development of the economy and the improvement of green energy awareness, more and more regions are using clean energy and installing a large number of solar power generation equipment. With the widespread use of photovoltaic power generation, many users have found that there are power adjustment fees, namely power fines, in the electricity bill, and the amount of fines is rel...
YT ELECTRIC has been offering a comprehensive range of key components for Automatic Power factor correction (APFC) and power quality solutions for many years. The rapid development of industry and infrastructure resulted in the increased usage of power electronic loads which demands a highly dynamic response time for reactive power compensation. Conventional reactive power compensation only with p...