Static VAR Generator (SVG) and Hybrid Compensation both solutions used in power systems to improve power quality and mitigate issues related to voltage and reactive power control. However, there are differences between the two approaches. Static VAR Generator (SVG): An SVG is a power electronic device used to compensate for reactive power in the transmission and distribution system. It operates by...
The relationship between capacitors and harmonics is very close, especially in power systems. The use of capacitors can affect the generation and propagation of harmonics, and are also easily affected by harmonics, leading to reduced performance or damage. Harmonic amplification In the power system, capacitors have a lower impedance to harmonics, so harmonic currents tend to flow through th...
The peak and effective value of harmonics When discussing the peak of harmonic currents, it's essential to first understand the fundamentals of harmonics. The effective value (RMS value) of a harmonic describes the average power of the harmonic component over one period, reflecting the equivalent extent to which the harmonic causes heating effects in the system. However, the peak of a harmonic (th...
In the PV Solar field, people carry out a variety of measures and strategies to make PV systems operate dependably and efficiently, and at the same time protect the quality of the electrical power supplied to the grid, which is power quality management. This is crucial for the stable operation of the entire power system. Let's delve deeper into some of the critical aspects of power quality managem...
Introduction To Capacitors And Reactors Reactance includes inductive reactance and capacitive reactance, and reactor includes inductive reactance (inductor) and capacitive reactance (capacitor). Inductance has the function of blocking AC and blocking DC, that is, in the AC circuit, the characteristics of inductive reactance are used to pass low-frequency DC and block high-frequency AC. The capacit...
What are the power quality problems of broadband oscillation? Broadband oscillations in power systems refer to low-frequency oscillations that occur over a wide range of frequencies. These oscillations can have a significant impact on system stability and can lead to voltage instability, power quality issues, and even blackouts if not properly managed. Here are some of the characteristics of broad...
kVAr and Amps in power quality Reactive Power (kVAR) Reactive power, measured in kilovolt-amperes reactive (kVAR), is the component of alternating current (AC) power that does not perform any actual work but is necessary for maintaining the voltage levels required for the active (real) power to do useful work. It is associated with the energy storage in inductive and capacitive elements of the pow...
Reasons of Neutral Current The neutral current is the current flowing through the neutral conductor in a multi-phase electrical system. In a perfectly balanced system, the sum of the currents in all phases should theoretically cancel each other out, resulting in zero neutral current. However, in practice, various factors cause current to flow in the neutral conductor. Reasons for Neutral Cur...