The reactive power consumed by the transformer is generally about 10% to 15% of its rated capacity, and its no-load reactive power is about 1/3 of the full load. Therefore, in order to improve power factor (PF) of the power system, the transformer should not operate at no-load or in a long-term low-load operation state. Vigorously improving the power factor of transformers, reducing line losses, a...
Low voltage automatic contactor switched capacitor banks or filter banks typically use a delay time of 30 – 40 seconds between steps. This delay time is chosen to ensure that the capacitors have discharged prior to being re-connected. The long delay time limits the autobank’s ability to track rapidly changing loads. The slow response time may result in an overload condition in filter b...
Hybrid power factor correction Hybrid Active power factor correction systems utilise power electronics and digital control to achieve active reactive current compensation for specific and high performance solutions. YTPQC hybrid power factor correction system is comprised from both capacitor based and Static Var Generator(SVG,Active Power Factor correction). Static Var Generator is use...
Why power factor is lower at power grid with solar? The active power and reactive power consumed by the system is fixed. When there is photovoltaic, photovoltaic provides active power, so the active power provided by the system decreases, and the reactive power remains unchanged, so the power factor decreases. If the active power provided by photovoltaics is close to the active power consumed by t...
Passive Harmonic Filter The simplest of all filters are the ones built using just resistors, capacitors and inductors. Such filters are called passive harmoinc filters, as they are constructed from passive components. In electronics, passive components are those which do not produce energy of their own. They are only capable of dissipating energy (in the case of resistors) or storing energy (in th...
We YT are the biggest manufacture of low voltage Static Var Generator and Active Harmonic Filter, all our factory take the quality as the most important positon. YT Incoming material Quality Control IQC check the raw materials, electronic components and enclosures from our suppliers before admitting to our warehouse. YT Process Quality Control In Process Quality Control, ...
Shanghai Yingtong Electric is the leading manufacture in low voltage Static Var Generator and Active Harmonic Filter. Static Var Generator SVG is a revolutional new power factor correction product with latest PFC technology. YTPQC-SVG utilises a high speed three level inverter that reacts to changes in reactive power, exchanging corrective reactive power into the system. YTPQC-SVG is an enti...
Power factor is the measure of how effectively the incoming power is used in an electrical system. A high power factor indicates that the power supplied to the electrical system is effectively used. A system with low power factor doesn’t effectively consume the incoming electric supply and results in losses. There is no power factor involved in DC circuits due to zero frequency. But, in AC c...