What is the power quality problems at sites with welding machines? The most common power quality problems associated with welding machines are voltage sags, harmonic pollution, and electromagnetic interference. Voltage sags can cause the welding machine to operate at a lower than expected output, resulting in poor weld quality. Harmonic distortion pollution can cause interference with other equipm...
What is difference between THD and TDD? While power electronics have created considerable energy savings, they can distort the quality of electrical power delivered through the building they serve, reducing the effectiveness and life span of the power electronics contained within that building. THD is described as the instantaneous value of the ratio of the root-mean-square (rms) of the harmonic c...
What are scenarios causing power factor displacements 1. Poorly designed electrical systems with inadequate power factor correction equipment. 2. Large inductive loads such as motors, transformers, and generators that cause lagging power factor. 3. Unbalanced three-phase loads that cause phase displacement of the current and voltage waveforms. 4. Unbalanced single-phase loads that cause current an...
Power Quality Power electronics make modern life possible and enable all other areas of innovation. Although stable power delivery seems like a simple problem, the design of a high-efficiency power transmission and conversion system is prone to several problems that reduce efficiency by reducing delivered power. Nonlinear components are needed in power electronics to control the flow of power and ...
Basic Information Downstream line-to-line voltage (V): 1). 208V/220V 2). 380V/400V/415V 3).440V/460V/480V 4).600V/660V/690V System Rated Frequency: 1). 50Hz 2). 60Hz System phase connection: 1). 3P4W 2). 3P3W Other Useful Information 1). Upstream short circuit power 2). Transformer rated power(kVA) 3). Short circuit impedance(6.5%?) 4). Max load(kW) 5). Ambient temperature 6). Rated Hu...
Microgrids are designed to operate at a fundamental frequency (50 or 60 Hz). However, certain types of loads generate voltage and/or current harmonics that increase power system heat losses. These harmonic losses reduce system efficiency, cause apparatus overheating and increase power costs. Besides that, the Distributed Generation (DG) is expected to play an important role in future power systems...
Achieving capable factory functional test requires meeting multiple criteria to ensure the highest quality product. These criteria include test capability and repeatability, system upgradability and supportability, and production scalability. Setting up new production test not only involves implementing new test systems, but also managing schedule risk and budget which are often impacted by techni...
For all clients, We adhere to quality-oriented, try our best to meet customer's technical requirement. Our client also has a good,professional technical team, they buy our modules to build cabinet locally in Australia. Since we worked with Australian clients, they have build Static Var Generator(SVG) panel, Active Harmonic Filter(AHF) panel, and hybrid SVG and AHF panel. This customer's visit gave...