For all clients, We adhere to quality-oriented, try our best to meet customer's technical requirement. Our client also has a good,professional technical team, they buy our modules to build cabinet locally in Australia. Since we worked with Australian clients, they have build Static Var Generator(SVG) panel, Active Harmonic Filter(AHF) panel, and hybrid SVG and AHF panel. This customer's visit gave...
YT ELECTRIC has been offering a comprehensive range of key components for Automatic Power factor correction (APFC) and power quality solutions for many years. The rapid development of industry and infrastructure resulted in the increased usage of power electronic loads which demands a highly dynamic response time for reactive power compensation. Conventional reactive power compensation only with p...
YTPQC-AHF Active Power Filter has been operating safely and stably in France YTPQC-AHF Active Power Harmonic Filter is an advanced power quality control equipment, which can compensate reactive power ,harmonics current and imbalance by setting parameters from friendly Human Machine Interface.This time French client purchased our Active Harmonic Filters mainly to improve Power Factor and mitigate h...
Power factor is a measurement of electrical system efficiency. Many utilities have a power factor penalty built into their rate structure to penalize users with a low power factor reading in their electrical system. To improve the power factor, the most common solution is to install a capacitor banks, But Static Var Generator is the best power factor correction product. There are 3 kinds of...
SVG (Static Var Generator) and conventional capacitor bank are both devices used in power systems for reactive power compensation, but they have significant differences in terms of operation, performance, and flexibility. Here's a comparison between SVG and conventional capacitor bank: 1. Operation: - SVG: SVG uses power electronics-based technology to dynamically control and r...
The reactive power consumed by the transformer is generally about 10% to 15% of its rated capacity, and its no-load reactive power is about 1/3 of the full load. Therefore, in order to improve power factor (PF) of the power system, the transformer should not operate at no-load or in a long-term low-load operation state. Vigorously improving the power factor of transformers, reducing line losses, a...
Low voltage automatic contactor switched capacitor banks or filter banks typically use a delay time of 30 – 40 seconds between steps. This delay time is chosen to ensure that the capacitors have discharged prior to being re-connected. The long delay time limits the autobank’s ability to track rapidly changing loads. The slow response time may result in an overload condition in filter b...
Hybrid power factor correction Hybrid Active power factor correction systems utilise power electronics and digital control to achieve active reactive current compensation for specific and high performance solutions. YTPQC hybrid power factor correction system is comprised from both capacitor based and Static Var Generator(SVG,Active Power Factor correction). Static Var Generator is use...